Effect of Macrosynthetic and Hybrid Fibers on Shear Behavior of Concrete Beams Reinforced with GFRP Bars

Dev, Amal and Chellapandian, Maheswaran and Prakash, Shanmugam Suriya (2020) Effect of Macrosynthetic and Hybrid Fibers on Shear Behavior of Concrete Beams Reinforced with GFRP Bars. Journal of Bridge Engineering, 25 (7). 04020031. ISSN 1084-0702

Full text not available from this repository. (Request a copy)

Abstract

Design of reinforced concrete (RC) bridge members with fiber-reinforced polymer (FRP) bars as internal reinforcement are usually governed by their serviceability parameters, such as crack width and deflection. This study investigates the effect of structural fibers on the shear behavior of RC beams with glass fiber-reinforced polymer (GFRP) rebar as longitudinal reinforcement. The objective of this study is to understand the efficiency of macrosynthetic polyolefin (PO) polymer and a hybrid combination of steel and PO fibers in improving the shear behavior of GFRP-reinforced beams. In total, 13 full-scale RC beams are cast with GFRP rebars as internal reinforcement and varying PO and hybrid fiber dosages. Three different fiber dosages by volume of concrete (vf), namely 0.35%, 0.70%, and 1.0% are considered. The beams are tested under three-point bending configuration with a shear span (a) to effective depth (d) ratio of 2.2 to simulate shear dominant behavior. Experimental results revealed that the addition of fibers increased the postcracking stiffness, peak load, and ductility when compared with control beams with no fibers. Soon after cracking, an excessive load drop in the control specimen is observed due to the low elastic modulus of GFRP rebars. The addition of PO and hybrid fibers reduced the load drop significantly and enhanced the postcracking performance by improving the aggregate interlock and through reduction of residual tensile stresses at the crack tip. The angle of the crack increased with an increase in fiber dosages, indicating the change of the failure mode from brittle shear tension to ductile flexure at higher fiber dosages (0.7% and 1.0%). The shear strength predictions obtained from ACI and RILEM recommendations are found to be very conservative when compared with the test results.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Dev, A.UNSPECIFIED
Chellapandian, MaheswaranUNSPECIFIED
Prakash, Shanmugam SuriyaUNSPECIFIED
Item Type: Article
Uncontrolled Keywords: Aggregate interlocks; Fiber reinforced polymer bars; Glass fiber reinforced polymer; Longitudinal reinforcement; Low elastic modulus; Residual tensile stress; Shear strength predictions; Three point bending;Bridges; Concrete beams and girders; Crack tips; Drops; Fiber reinforced plastics; Polymers; Rebar; Shear flow; Steel fibers
Subjects: Civil Engineering
Divisions: Department of Civil Engineering
Depositing User: . LibTrainee 2021
Date Deposited: 28 Jul 2021 07:23
Last Modified: 28 Jul 2021 07:23
URI: http://raiithold.iith.ac.in/id/eprint/8554
Publisher URL: http://doi.org/10.1061/(ASCE)BE.1943-5592.0001557
OA policy: https://v2.sherpa.ac.uk/id/publication/11543
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 8554 Statistics for this ePrint Item