Low cost, flexible and disposable SnSe2 based photoresponsive ammonia sensor for detection of ammonia in urine samples

Veeralingam, Sushmitha and Sahatiya, Parikshit and Badhulika, Sushmee (2019) Low cost, flexible and disposable SnSe2 based photoresponsive ammonia sensor for detection of ammonia in urine samples. Sensors and Actuators B: Chemical, 297. p. 126725. ISSN 09254005 (In Press)

Full text not available from this repository. (Request a copy)

Abstract

A low cost, flexible, disposable sensing platform which can detect excess ammonia in biological fluids with an enhanced response is of utmost importance in medical diagnostics for early detection of kidney dysfunction, gastrointestinal bleeding, urinary tract related diseases. This report is the first demonstration of direct growth of 2D Tin Diselenide (SnSe2) on cellulose paper by the hydrothermal method for enhanced photoresponsive ammonia detection in urine samples. X-Ray Diffraction (XRD) and Raman studies confirmed the formation of SnSe2 while field emission scanning electron microscopy (FESEM) studies revealed the uniform distribution of SnSe2 nanoflakes on cellulose paper. The SnSe2 based sensor, when irradiated with Near Infra Red (NIR) light exhibited excellent responsivity, detectivity and external quantum efficiency of 70 mA/W, 11 × 107 jones and 4.5% respectively. Furthermore, the photoresponsive sensor responded to a wide range of ammonia concentrations (50μM - 500μM), with a sensitivity of 0.93 m μM−1 in comparison to 0.73 m μM−1 (without illumination) and a limit of detection (LOD) of 11.3μM which is far more superior in performance than sensors fabricated using sophisticated techniques. Motivated by this enhanced response of the sensor to ammonia in the aqueous medium, it was further employed in detecting ammonia in human urine samples. The mechanism of detection can be attributed to NIR induced oxygen desorption on the surface of 2D- SnSe2, hence creating more vacant sites for interaction with ammonia molecules. The strategy presented in this work could be a step ahead in developing low cost, point-of-care diagnostics to detect various diseases.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Badhulika, Sushmeeorcid.org/0000-0003-3237-3031
Item Type: Article
Uncontrolled Keywords: Ammonia sensor, Chemiresistive sensor, Hydrothermal synthesis, Photoresponsive sensor, Tin diselenide
Subjects: Electrical Engineering
Divisions: Department of Electrical Engineering
Depositing User: Team Library
Date Deposited: 22 Jul 2019 09:20
Last Modified: 22 Jul 2019 09:20
URI: http://raiithold.iith.ac.in/id/eprint/5770
Publisher URL: http://doi.org/10.1016/j.snb.2019.126725
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 5770 Statistics for this ePrint Item