Improved Design Shear Method for the Bolted Cold-Formed Steel Clip-Angle Connector

Madhavan, Mahendrakumar (2023) Improved Design Shear Method for the Bolted Cold-Formed Steel Clip-Angle Connector. Journal of Structural Engineering, 149 (5). 04023048. ISSN 0733-9445

[img] Text
jou_str_eng-149-5.pdf - Published Version

Download (4MB)

Abstract

In this paper, the ultimate shear capacity of the 3-bolt cold-formed steel clip-angle between the cold-formed steel (CFS) beam and column is evaluated through 54 laboratory tests. A series of experiments were conducted by varying (1) thickness, and (2) aspect ratio (L/D) of clip-angles for different depths (D) and widths (A). The experimental program consists of three phases of tests: (1) Phase-I: direct shear load tests on clip-angle attached to a CFS column through 4.6-grade bolts; (2) Phase-II: CFS column replaced with a hot-rolled steel (HRS) column, since the CFS column experienced bearing failure in Phase-I; and (3) Phase-III: 10.9-grade bolts used instead of 4.6, as the 4.6-grade bolts subjected to bolt shear failure in Phase-II. Failure modes observed in the test specimens are (1) shear local buckling of clip-angle; (2) column bearing failure; (3) bolt shear failure; and (4) tear failure in clip-angle. Design shear equations from the literature, for the bolted clip-angle, were found to be inefficient for the high-grade steel (fy=375 MPa to 550 MPa), and conservative for the commonly available low-grade steel (fy=275 MPa). Hence a new shear strength equation is suggested for the clip-angle from the collated data of the present study and past research work. A comparative study between 2-bolt and 3-bolt clip-angle configurations was conducted to evaluate the increase in shear strength. Reliability studies were conducted, and corresponding resistance and safety factors were suggested for the design shear strength calculation corresponding to load and resistance factor design (LRFD), limit state design (LSD), and allowable strength design (ASD) methods.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Madhavan, Mahendrakumarhttps://orcid.org/0000-0002-3144-5278
Item Type: Article
Uncontrolled Keywords: Bolted clip-angle; Cold-formed steel beam-to-column connection; Column bearing failure; Reliability analysis; Aspect ratio; Failure (mechanical); Hot rolled steel; Hot rolling; Load testing; Reliability analysis; Safety factor; Software testing; Studs (structural members); Beam-to-column connections; Bearing failures; Bolted clip-angle; Clip angles; Cold-formed steel; Cold-formed steel beam-to-column connection; Cold-formed steel beams; Cold-formed steel columns; Column bearing failure; Shears strength; Bolts
Subjects: Civil Engineering
Civil Engineering > Structural engineering and underground construction
Divisions: Department of Civil Engineering
Depositing User: Mr Nigam Prasad Bisoyi
Date Deposited: 27 Sep 2023 04:56
Last Modified: 27 Sep 2023 04:56
URI: http://raiithold.iith.ac.in/id/eprint/11703
Publisher URL: https://doi.org/10.1061/JSENDH.STENG-11666
OA policy: https://www.sherpa.ac.uk/id/publication/11579
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 11703 Statistics for this ePrint Item