A prospective evaluation of breast thermography enhanced by a novel machine learning technique for screening breast abnormalities in a general population of women presenting to a secondary care hospital

Bansal, Richa and Collison, Sathiakar and Krishnan, Lakshmi and Aggarwal, Bharat and Vidyasagar, Mathukumalli and Kakileti, Siva Teja and Manjunath, Geetha (2023) A prospective evaluation of breast thermography enhanced by a novel machine learning technique for screening breast abnormalities in a general population of women presenting to a secondary care hospital. Frontiers in Artificial Intelligence, 5. ISSN 2624-8212

[img] Text
frai-05-1050803.pdf - Published Version

Download (978kB)

Abstract

Artificial intelligence-enhanced breast thermography is being evaluated as an ancillary modality in the evaluation of breast disease. The objective of this study was to evaluate the clinical performance of Thermalytix, a CE-marked, AI-based thermal imaging test, with respect to conventional mammography. Methods: A prospective, comparative study performed between 15 December 2018 and 06 January 2020 evaluated the performance of Thermalytix in 459 women with both dense and nondense breast tissue. Both symptomatic and asymptomatic women, aged 30–80 years, presenting to the hospital underwent Thermalytix followed by 2-D mammography and appropriate confirmatory investigations to confirm malignancy. The radiologist interpreting the mammograms and the technician using the Thermalytix tool were blinded to the others' findings. The statistical analysis was performed by a third party. Results: A total of 687 women were recruited, of whom 459 fulfilled the inclusion criteria. Twenty-one malignancies were detected (21/459, 4.6%). The overall sensitivity of Thermalytix was 95.24% (95% CI, 76.18–99.88), and the specificity was 88.58% (95% CI, 85.23–91.41). In women with dense breasts (n = 168, 36.6%), the sensitivity was 100% (95% CI, 69.15–100), and the specificity was 81.65% (95% CI, 74.72–87.35). Among these 168 women, 37 women (22%) were reported as BI-RADS 0 on mammography; in this subset, the sensitivity of Thermalytix was 100% (95% CI, 69.15–100), and the specificity was 77.22% (95% CI, 69.88–83.50). Conclusion: Thermalytix showed acceptable sensitivity and specificity with respect to mammography in the overall patient population. Thermalytix outperformed mammography in women with dense breasts and those reported as BI-RADS 0.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Vidyasagar, MathukumalliUNSPECIFIED
Item Type: Article
Uncontrolled Keywords: artificial intelligence; breast density; mammography; prospective studies; thermography
Subjects: Electrical Engineering
Electrical Engineering > Electrical and Electronic
Divisions: Department of Electrical Engineering
Depositing User: Mr Nigam Prasad Bisoyi
Date Deposited: 16 Aug 2023 10:50
Last Modified: 16 Aug 2023 10:50
URI: http://raiithold.iith.ac.in/id/eprint/11534
Publisher URL: https://doi.org/10.3389/frai.2022.1050803
OA policy: https://www.sherpa.ac.uk/id/publication/36361
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 11534 Statistics for this ePrint Item